Gecric Integrity

Assured quality delivered!

icon_widget_image Monday-Friday: 9am to 5pm; Satuday: 10ap to 2pm icon_widget_image Konney Kukulu Street, Mempeasem, East Legon icon_widget_image + (233) 30-296-1433 + (233) 55-253-2326 icon_widget_image info@gecricintegrity.com
Image Alt
CASE STUDY

Cleaning and Inspection of Separators

Notable among our projects is the Riser Hookup operation done by Rope Access for a Floating Regasification Unit in Accra.

Cleaning and Inspection of Separators

Location: Atuabo, Western Region
The objective of this project was to thoroughly clean and perform inspection according to API
510 on the inlet separators and Low Temperature Separator.
The project scope covered:

  • Purging
  • Flange Management
  • Pressure Testing
  • Cleaning
  • Replacement of Mist Extractor
  • Non-Destructive Testing
  • API 510 Assessment (Remaining Life assessment, Fitness for service Assessment)

The project was successfully completed in a week. The asset was found to be in working after
project completion. The client found results beyond satisfactory.